Part Number Hot Search : 
3XXXN 024410A PEX811 T930N MC7808C 25C05ZA 21A15 MC33288
Product Description
Full Text Search
 

To Download W2642A Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  agilent W2642A displayport aux channel controller data sheet features ? stand alone graphic user interface ? lan interface ? read/write capability for edid (electronic display identification eprom) over aux ? read/write capability for dpcd (displayport configuration data) over aux ? load/read dpcd or edid data for displayport sink emulation device ? load/store dpcd or edid data files for quick configuration of sink emulation devices. ? hot plug event generation ? method 1 and method 2 edid read/writes ? api (application program interface) used for n5990a factory automation software and infiniium displayport compliance application, u7232a ? upgrade paths for link layer compliance test, hdcp compliance testing and aux channel protocol analysis complete your displayport toolset with test automation and aux channel control capability agilent technologies W2642A displayport aux channel controller 1 enables fast, easy and automated testing for the physical layer as well as flexible debug capability for new displayport designs. displayport test and design engineers can now run physical layer tests fully unattended thus doubling their productivity. when used with the W2642A, the agilent displayport source and sink compliance test solutions which are already vesa 2 certified for official displayport compliance testing can become fully automatic. in addition to the productivity gains, this new capability helps eliminate operator errors and offers complete device test status tracking and repeatable results. 1 the W2642A aux channel controller is based on the quantum data 882e product. agilent intellectual property was developed separately and is placed in the 882e to control the displayport aux channel . 2 video electronics standards association (www.vesa.org)
2 a standard process to ascertain the functionality of any displayport device is to see if you can communicate with it through the standard interface, the aux channel. with a pc as the host, a graphical user interface (gui) is used to control the W2642A through a lan connection. through this gui, you can check the operation of a displayport source or sink over the aux channel. source testing figure 2 shows the setup screen configured for testing a source. note that the W2642A is set up as a sink. the W2642A can initiate a source read /write process by asserting a hot plug event. this event can have varying lengths. some events can be specified as within the range to be interpreted as an interrupt, while others can be outside this range. you can use this feature to check the source driver interpretation of the event. the W2642A can appear as any sink device by merely loading in that devices edid file. you can acquire that file by connecting to the device, configuring the W2642A as a source and downloading the sinks edid data. by using many different sets of valid edids, you can check the default setup of a source as a function of the parameters read from the edid, such as timing information or resolution. figure 2: setup screen for the W2642A gui for source test. setup screen edid load figure 3: edid tab screen for the W2642A gui stand alone aux channel control
3 the W2642A can provide any dpcd data desired by merely loading from a dpcd file that has acceptable data or by creating that data independently. standard dpcd data can be acquired from a device by connecting to it and configuring the W2642A as a source and downloading its dpcd data, or by writing to it directly using the dpcd io capabilities shown in figure 4. sink testing figure 5 shows the setup screen configured for testing a sink. note that the W2642A is set up as a source. the W2642A configured as a source can read/write edid or dpcd. in this mode, data that is read from the sink device can be compared with expected behavior, for example, symbol lock. this is particularly convenient for testing jitter tolerance on a sink or verifying that the sink state registers are operating as expected. when the W2642A is acting as a source, the edid and dpcd screens are identical as in figures 4 and 5 and represent actual data state of the sink device being tested when the read from dp function is enabled. in any verification process you must verify the edid content and i2c over aux communication using the source reading of edid. you can verify whether your sink device works in either edid communication method as stipulated in the displayport standard using the method 1 or method 2 selection in the setup tab. figure 4: dpcd tab screen for the W2642A gui dpcd data load setup screen figure 5: setup screen on the W2642A gui configured for sink test.
4 test automation the application program interface used by the W2642A gui to control the W2642A is also used in test automation software provided by agilent for source and sink physical layer testing. for source testing, this feature is provided in the u7232a displayport source compliance test software, and is available on versions later than version 1.7. the u7232a software was designed specifically for test automation and will run unattended after the device capabilities are defined and the scope connection details are entered in the software. this software can run the full compliance test conditions as specified in the displayport compliance test specification or can run specialized user defined procedures. see table 2 for the full equipment set for the elements of the automated displayport source solution. for sink testing, the n5990a factory automation software used with other standards such as sata, pci express ? and hdmi, provides the necessary control to the agilent equipment and the device under test. n5990a option 155 provides the control to the device under test through the W2642A option aux channel controller to set the state and query the registers, for example the prbs counter register must be able to reset to 0, count a given number of errors, be queried, reset and then count errors during the jitter tolerance test and read again. the software guides you through the connection process and controls the stress signal generator as identified in the compliance test specification. see table 1 for full automation solution requirements. figure 6. the W2642A aux channel controller in a source test configuration figure 7. the W2642A aux channel controller in a sink test configuration
5 figure 8: w2641a displayport test point access adaptor. test connectivity a key component in source or sink test solutions is the w2641a test point access adaptor. the w2641a was designed with aux channel access through a 14-pin digital connector. an adaptor board as illustrated in figures 6 and 7, connects to the device under test to the W2642A through a displayport cable. the adaptor board, and displayport and lan cables, are shipped with each W2642A. ordering displayport solutions with the W2642A model number description quantity W2642A displayport aux channel controller 1 w2641a displayport test point access adapter 1 n5460a smp right angle cables (recommended) n4903a j-bert 1 option g07 150 mb/s to 7 gb/s 1 option j10 jitter injection 1 option j11 ssc clocking 1 n4915a-006 isi generator 1 n5990a-010,-155 test automation software 1 ea. for calibration bit-dp-rtf-0001 receptacle displayport fixture 1 dsa90804a infiniium series oscilloscope 1 sink test when purchasing a full automated sink test solution, order the following: table 1: sink test solution elements expanding your toolset because the W2642A aux channel controller is based on the quantum data 882e instrument you get access to all the capabilities that quantum data provides with this platform. quantum data is the leader for displayport link layer compliance testing, displayport high definition content protection and also for displayport aux channel analysis. these capabilities are not shipped with the 882e but they are available as aftermarket upgrades through your quantum data distributor.
6 model number description quantity n5460a phase matched pair: right angle smp-to-sma male (optional, recommended) 1, 2, 4 e4809-23801 cable plug in tool (recommended for n5460a cables) 1 e4809-23802 cable removal tool (required for n5460a cables) 1 n4235-61602 phased matched pair: smp-to-sma cables (standard replacement cables for w2641a) 1, 2, 4 w2641a test accessories model number description quantity n9398c blocking capacitor 1 11636b power dividers 4 15442a sma cable kit(4 cables) 2 15435a 150-ps transition time converter 4 1250-2206 50-ohm terminations 4 bw-s4w2+ mini circuits 4 db attenuator 2 bw-s54w2+ mini circuits 5 db attenuator 2 bw-s10w2+ mini circuits 10 db attenuator 2 1810-0118 sma (m) 50 termination 33sma-q50-0-4 sma push-on adaptors from s.m. electronics (or equivalent) test accessories model number description quantity W2642A displayport aux channel controller 1 dsa90804a infiniium series realtime oscilloscope 1 1169a probe amplifiers (optional) 1,2, or 4 n5380a sma differential probe heads (optional) 1, 2 or 4 u7232a (opt028) displayport source test compliance software 1 w2641a displayport test point adapter (see w2641a accessories below) 1 n5990a-255 interface to n5990a complementary test automation software platform, optional 1 source test when purchasing a full automated source test solution, order the following: table 2: source test solution elements ordering displayport solutions with the W2642A (continued)
7 related agilent literature publication title publication type publication number infiniium 90000 series oscilloscopes data sheet 5989-7819en u7232a displayport compliance test software data sheet 5989-7198en agilent method of implementation for displayport sink compliance test application note 5989-9147en n4903a jbert data sheet 5989-2899en n4915a-006 displayport isi generator data sheet 5989-8688en parbert tmds generator data sheet 5989-5537en n5990a test automation software platform data sheet 5989-5483en w2641a displayport test point access adapter data sheet 5989-7274en agilent technologies oscilloscopes multiple form factors from 20 mhz to >90 ghz | industry leading specs | powerful applications
windows ? is a u.s. registered trademark of microsoft corporation. pci express ? is a registered trademark of the pci sig remove all doubt our repair and calibration services will get your equipment back to you, performing like new, when promised. you will get full value out of your agilent equipment throughout its lifetime. your equipment will be serviced by agilent-trained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. you will always have the utmost confidence in your measurements. agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance onsite education and training, as well as design, system integration, and project management. for more information on repair and calibration services, go to www.agilent.com/find/removealldoubt www.agilent.com/find/open agilent open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. agilent offers open connectivity for a broad range of system-ready instruments, open industry software, pc-standard i/o and global support, which are combined to more easily integrate test system development. www.agilent.com/find/emailupdates get the latest information on the products and applications you select. www.agilent.com/find/agilentdirect quickly choose and use your test equipment solutions with confidence. agilent email updates agilent direc t www.lxistandard.org lxi is the lan-based successor to gpib, providing faster, more ef? cient connectivity. agilent is a founding member of the lxi consortium. www.agilent.com www.agilent.com/? nd/displayportaux for more information on agilent technologies products, applications or services, please contact your local agilent office. the complete list is available at: www.agilent.com/? nd/contactus americas canada (877) 894-4414 latin america 305 269 7500 united states (800) 829-4444 asia paci? c australia 1 800 629 485 china 800 810 0189 hong kong 800 938 693 india 1 800 112 929 japan 0120 (421) 345 korea 080 769 0800 malaysia 1 800 888 848 singapore 1 800 375 8100 taiwan 0800 047 866 thailand 1 800 226 008 europe & middle east austria 01 36027 71571 belgium 32 (0) 2 404 93 40 denmark 45 70 13 15 15 finland 358 (0) 10 855 2100 france 0825 010 700* *0.125 /minute germany 07031 464 6333** **0.14 /minute ireland 1890 924 204 israel 972-3-9288-504/544 italy 39 02 92 60 8484 netherlands 31 (0) 20 547 2111 spain 34 (91) 631 3300 sweden 0200-88 22 55 switzerland 0800 80 53 53 united kingdom 44 (0) 118 9276201 other european countries: www.agilent.com/? nd/contactus revised: july 17, 2008 product speci? cations and descriptions in this document subject to change without notice. ? agilent technologies, inc. 2008 printed in usa, november 30, 2008 5989-9973en


▲Up To Search▲   

 
Price & Availability of W2642A

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X